使用恒溫恒濕試驗箱時特異故障的處理

作者: 來源: 日期:2018/9/23 19:04:49 人氣:3293
       特異故障:恒溫恒濕試驗箱白天工作時出現頻繁“跳機”現象,到了晚上制冷效果正常。
 
  分析:晚上制冷效果正常,說明制冷系統和電路系統工作正常,這說明是恒溫恒濕試驗箱機外原因造成的,原因是冷凝器散熱不良。
 
  檢查:冷凝器散熱不良原因有:(1)冷凝器表明太臟;(2)制冷系統內有空氣;(3)周圍空氣不流動;(4)周圍環境溫度太高;(5)冷凝器內表面結油膜。
 
  處理結果:該試驗箱晚上制冷效果正常,這就排除了上述原因中的(1)、(2)、(3)和(5)。將試驗箱移到別處便不再“跳機”。由此判定是恒溫恒濕試驗箱靠近熱源造成的冷凝器散熱不良。
 
  解決方案:將恒溫恒濕試驗箱移到遠離熱源且通風的地方,即可排除故障。
 